The ARGO-YBJ experiment has been taking data for nearly 2 years. In order to monitor continuously the performance of the Resistive Plate Chamber detectors and to study the daily temperature effects on the detector performance, a cosmic ray muon telescope was setup near the carpet detector array in the ARGO-YBJ laboratory. Based on the measurements performed using this telescope, it is found that, at the actual operating voltage of 7.2kV, the temperature effect on the RPC time resolution is about 0.04ns/degrees C and on the particle detection efficiency is about 0.03%/degrees C. Based on these figures we conclude that the environmental effects do not affect substantially the angular resolution of the ARGO-YBJ detector. (C) 2009 Elsevier B.V. All rights reserved.

Aielli, G., Bacci, C., Bartoli, B., Bernardini, P., Bi, X.j., Bleve, C., et al. (2009). Temperature effect on RPC performance in the ARGO-YBJ experiment. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 608(2), 246-250 [10.1016/j.nima.2009.07.020].

Temperature effect on RPC performance in the ARGO-YBJ experiment

BUSSINO, Severino Angelo Maria;MARI, Stefano Maria;Montini P;Ruggieri F;
2009-01-01

Abstract

The ARGO-YBJ experiment has been taking data for nearly 2 years. In order to monitor continuously the performance of the Resistive Plate Chamber detectors and to study the daily temperature effects on the detector performance, a cosmic ray muon telescope was setup near the carpet detector array in the ARGO-YBJ laboratory. Based on the measurements performed using this telescope, it is found that, at the actual operating voltage of 7.2kV, the temperature effect on the RPC time resolution is about 0.04ns/degrees C and on the particle detection efficiency is about 0.03%/degrees C. Based on these figures we conclude that the environmental effects do not affect substantially the angular resolution of the ARGO-YBJ detector. (C) 2009 Elsevier B.V. All rights reserved.
2009
Aielli, G., Bacci, C., Bartoli, B., Bernardini, P., Bi, X.j., Bleve, C., et al. (2009). Temperature effect on RPC performance in the ARGO-YBJ experiment. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 608(2), 246-250 [10.1016/j.nima.2009.07.020].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/119801
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 67
  • ???jsp.display-item.citation.isi??? 48
social impact