A novel fault detection and ride-through method for the three-phase 4-Leg Inverter (3Phi4L Inverter) used in off-grid applications is addressed in this paper. Open circuit and short circuit faults of the power devices located in the 3 Phi 4 mathrm{~L} Inverter have been theoretically analyzed. Hence, the fault detection and converter protection strategy has been implemented using a combination of a resonant controller in the alpha beta frame and a repetitive observer. The proposed strategy has been at first validated by means of simulation results performed in MATLAB/Simulink environment. The fault detection and ride-through algorithm has been then implemented in FPGA using LabVIEW environment and full experimental verification are performed on the prototype of the three-phase 4-leg inverter.

Tang, M., Zanchetta, P., di Benedetto, M., Lidozzi, A., Solero, L. (2021). Fault Detection and Management of the Three-Phase 4-Leg Voltage Source Inverter. In 2021 IEEE Energy Conversion Congress and Exposition, ECCE 2021 - Proceedings (pp.3615-3622). Institute of Electrical and Electronics Engineers Inc. [10.1109/ECCE47101.2021.9595966].

Fault Detection and Management of the Three-Phase 4-Leg Voltage Source Inverter

di Benedetto M.;Lidozzi A.;Solero L.
2021-01-01

Abstract

A novel fault detection and ride-through method for the three-phase 4-Leg Inverter (3Phi4L Inverter) used in off-grid applications is addressed in this paper. Open circuit and short circuit faults of the power devices located in the 3 Phi 4 mathrm{~L} Inverter have been theoretically analyzed. Hence, the fault detection and converter protection strategy has been implemented using a combination of a resonant controller in the alpha beta frame and a repetitive observer. The proposed strategy has been at first validated by means of simulation results performed in MATLAB/Simulink environment. The fault detection and ride-through algorithm has been then implemented in FPGA using LabVIEW environment and full experimental verification are performed on the prototype of the three-phase 4-leg inverter.
2021
978-1-7281-5135-9
Tang, M., Zanchetta, P., di Benedetto, M., Lidozzi, A., Solero, L. (2021). Fault Detection and Management of the Three-Phase 4-Leg Voltage Source Inverter. In 2021 IEEE Energy Conversion Congress and Exposition, ECCE 2021 - Proceedings (pp.3615-3622). Institute of Electrical and Electronics Engineers Inc. [10.1109/ECCE47101.2021.9595966].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/398200
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact