Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
Benvenuti nell'Anagrafe della Ricerca d'Ateneo
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a
satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A
ton-level liquid scintillator detector will be placed at about 30 m from a core
of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be
measured with sub-percent energy resolution, to provide a reference spectrum
for future reactor neutrino experiments, and to provide a benchmark measurement
to test nuclear databases. A spherical acrylic vessel containing 2.8 ton
gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon
Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full
coverage. The photoelectron yield is about 4500 per MeV, an order higher than
any existing large-scale liquid scintillator detectors. The detector operates
at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The
detector will measure about 2000 reactor antineutrinos per day, and is designed
to be well shielded from cosmogenic backgrounds and ambient radioactivities to
have about 10% background-to-signal ratio. The experiment is expected to start
operation in 2022.
Collaboration, J., Abusleme, A., Adam, T., Ahmad, S., Aiello, S., Akram, M., et al. (2020). TAO Conceptual Design Report: A Precision Measurement of the Reactor
Antineutrino Spectrum with Sub-percent Energy Resolution.
TAO Conceptual Design Report: A Precision Measurement of the Reactor
Antineutrino Spectrum with Sub-percent Energy Resolution
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a
satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A
ton-level liquid scintillator detector will be placed at about 30 m from a core
of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be
measured with sub-percent energy resolution, to provide a reference spectrum
for future reactor neutrino experiments, and to provide a benchmark measurement
to test nuclear databases. A spherical acrylic vessel containing 2.8 ton
gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon
Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full
coverage. The photoelectron yield is about 4500 per MeV, an order higher than
any existing large-scale liquid scintillator detectors. The detector operates
at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The
detector will measure about 2000 reactor antineutrinos per day, and is designed
to be well shielded from cosmogenic backgrounds and ambient radioactivities to
have about 10% background-to-signal ratio. The experiment is expected to start
operation in 2022.
Collaboration, J., Abusleme, A., Adam, T., Ahmad, S., Aiello, S., Akram, M., et al. (2020). TAO Conceptual Design Report: A Precision Measurement of the Reactor
Antineutrino Spectrum with Sub-percent Energy Resolution.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/401610
Citazioni
ND
ND
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.