Error in Table In the original publication [1], there was a mistake in **Table 1. Experimental methods applied to determine walls’ U-value** as published. There has been a change in the commas in the costs expressed in Euros during the production process of the published version of the paper. For example, the heat flow plate has a cost of 700  , but in the published version it is 70,000  . This is an issue related to spaces and commas. The corrected **Table 1. Experimental methods applied to determine walls’ U-value** appears below. The authors state that the scientific conclusions are unaffected. The original publication has also been updated. (Table presented.).

Evangelisti, L., Scorza, A., De Lieto Vollaro, R., Sciuto, S.A. (2022). Correction: Comparison between Heat Flow Meter (HFM) and Thermometric (THM) Method for Building Wall Thermal Characterization: Latest Advances and Critical Review (Sustainability, (2022), 14, (693), 10.3390/su14020693) [10.3390/su142013398].

Correction: Comparison between Heat Flow Meter (HFM) and Thermometric (THM) Method for Building Wall Thermal Characterization: Latest Advances and Critical Review (Sustainability, (2022), 14, (693), 10.3390/su14020693)

Evangelisti L.
;
Scorza A.
Writing – Review & Editing
;
De Lieto Vollaro R.;Sciuto S. A.
2022-01-01

Abstract

Error in Table In the original publication [1], there was a mistake in **Table 1. Experimental methods applied to determine walls’ U-value** as published. There has been a change in the commas in the costs expressed in Euros during the production process of the published version of the paper. For example, the heat flow plate has a cost of 700  , but in the published version it is 70,000  . This is an issue related to spaces and commas. The corrected **Table 1. Experimental methods applied to determine walls’ U-value** appears below. The authors state that the scientific conclusions are unaffected. The original publication has also been updated. (Table presented.).
2022
Evangelisti, L., Scorza, A., De Lieto Vollaro, R., Sciuto, S.A. (2022). Correction: Comparison between Heat Flow Meter (HFM) and Thermometric (THM) Method for Building Wall Thermal Characterization: Latest Advances and Critical Review (Sustainability, (2022), 14, (693), 10.3390/su14020693) [10.3390/su142013398].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/435627
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact