The Gas Phase Photoemission beamline at Elettra has been commissioned with outstanding success. All photoabsorption spectra taken between 90 and 900 eV have shown resolution which is equal to or higher than any published spectra. The monochromator is a variable angle spherical grating instrument (plane mirror and grating between entrance and exit slits), with an undulator as the source. Some of the problems encountered in commissioning and their solutions are discussed. In particular the calibration is complicated by the fact that an infinite number of angle pairs of the mirror and grating exist for a particular photon energy, whereas only one angle pair gives the highest resolution. A second problem is that the resolution is so high that above about 80 eV, it is much smaller than the lifetime broadening of any known absorption resonance, making any determination of resolution difficult. The experimental chambers available for users are described together with some examples of spectra which have been taken. (C) 1999 Elsevier Science B.V. All rights reserved.

Blyth, R.r., Delaunay, R., Zitnik, M., Krempasky, J., Krempaska, R., Slezak, J., et al. (1999). The high resolution Gas Phase Photoemission beamline, Elettra RID G-7348-2011. JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 103, 959-964.

The high resolution Gas Phase Photoemission beamline, Elettra RID G-7348-2011

STEFANI, Giovanni;
1999-01-01

Abstract

The Gas Phase Photoemission beamline at Elettra has been commissioned with outstanding success. All photoabsorption spectra taken between 90 and 900 eV have shown resolution which is equal to or higher than any published spectra. The monochromator is a variable angle spherical grating instrument (plane mirror and grating between entrance and exit slits), with an undulator as the source. Some of the problems encountered in commissioning and their solutions are discussed. In particular the calibration is complicated by the fact that an infinite number of angle pairs of the mirror and grating exist for a particular photon energy, whereas only one angle pair gives the highest resolution. A second problem is that the resolution is so high that above about 80 eV, it is much smaller than the lifetime broadening of any known absorption resonance, making any determination of resolution difficult. The experimental chambers available for users are described together with some examples of spectra which have been taken. (C) 1999 Elsevier Science B.V. All rights reserved.
1999
Blyth, R.r., Delaunay, R., Zitnik, M., Krempasky, J., Krempaska, R., Slezak, J., et al. (1999). The high resolution Gas Phase Photoemission beamline, Elettra RID G-7348-2011. JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 103, 959-964.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/115195
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 205
social impact