pH/thermosensitive hydrogels whose thermosensitivity is activated by the electrostatic interaction of the pH-sensitive units with a hydrophobic bioactive compound are proposed here as sensor-based self-regulated drug delivery systems. Poly(N-isopropylacrylamide-co-acrylamide-co-aminoethylacrylamide) (poly(NIPAAm-co-AAm-co-AEAAm)) was prepared as a new pH/thermoresponsive polymer by hydrolysis of poly(N-isopropylacrylamide-co-acrylamide (poly(NIPAAm-co-AAm)) at high temperature (120 degrees C) in the presence of ethylenediamine. Owing to the hydrophilicity of the inserted amine, the copolymers lose the thermosensitivity at physiological temperature and have a slow-phase transition at temperatures much higher than that of the human body. However, when the positively charged amine groups of the pH-sensitive units bind electrostatically with the negatively charged drug diclofenac, the copolymers retrieve the thermosensitivity. Poly(NIPAAm-co-AAm-co-AEAAm) was transformed into pH/thermoresponsive stable microspheres by an original approach based on crosslinking of the amine groups of aminoethylacrylamide (AEAAm) with glutaraldehyde at a temperature slightly below the lower critical solution temperature. The swelling/deswelling processes of microspheres occur only after the interaction of poly(NIPAAm-co-AAm-co-AEAAm) with the negatively charged drug diclofenac. The pH/temperature-sensitive microgels and dicofenac act as sensors and as the triggering agent, respectively. Conductometric titration reveals that the thermosensitivity of poly(NIPAAm-co-AAm-co-AEAAm) is retrieved when just half of its amino groups are complexed with diclofenac. (c) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2013.

Fundueanu, G., Constantin, M., Asmarandei, I., Harabagiu, V., Ascenzi, P., Simionescubc, (2013). The thermosensitivity of pH/thermoresponsive microspheres activated by the electrostatic interaction of pH-sensitive units with a bioactive compound. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH. PART A, 101(6), 1661-1669 [10.1002/jbm.a.34469].

The thermosensitivity of pH/thermoresponsive microspheres activated by the electrostatic interaction of pH-sensitive units with a bioactive compound

ASCENZI, Paolo;
2013-01-01

Abstract

pH/thermosensitive hydrogels whose thermosensitivity is activated by the electrostatic interaction of the pH-sensitive units with a hydrophobic bioactive compound are proposed here as sensor-based self-regulated drug delivery systems. Poly(N-isopropylacrylamide-co-acrylamide-co-aminoethylacrylamide) (poly(NIPAAm-co-AAm-co-AEAAm)) was prepared as a new pH/thermoresponsive polymer by hydrolysis of poly(N-isopropylacrylamide-co-acrylamide (poly(NIPAAm-co-AAm)) at high temperature (120 degrees C) in the presence of ethylenediamine. Owing to the hydrophilicity of the inserted amine, the copolymers lose the thermosensitivity at physiological temperature and have a slow-phase transition at temperatures much higher than that of the human body. However, when the positively charged amine groups of the pH-sensitive units bind electrostatically with the negatively charged drug diclofenac, the copolymers retrieve the thermosensitivity. Poly(NIPAAm-co-AAm-co-AEAAm) was transformed into pH/thermoresponsive stable microspheres by an original approach based on crosslinking of the amine groups of aminoethylacrylamide (AEAAm) with glutaraldehyde at a temperature slightly below the lower critical solution temperature. The swelling/deswelling processes of microspheres occur only after the interaction of poly(NIPAAm-co-AAm-co-AEAAm) with the negatively charged drug diclofenac. The pH/temperature-sensitive microgels and dicofenac act as sensors and as the triggering agent, respectively. Conductometric titration reveals that the thermosensitivity of poly(NIPAAm-co-AAm-co-AEAAm) is retrieved when just half of its amino groups are complexed with diclofenac. (c) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2013.
2013
Fundueanu, G., Constantin, M., Asmarandei, I., Harabagiu, V., Ascenzi, P., Simionescubc, (2013). The thermosensitivity of pH/thermoresponsive microspheres activated by the electrostatic interaction of pH-sensitive units with a bioactive compound. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH. PART A, 101(6), 1661-1669 [10.1002/jbm.a.34469].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/119683
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 13
social impact