The ARGO-YBJ experiment is an air shower detector for gamma ray astronomy and cosmic ray studies
with an energy threshold of ~500 GeV. Working in “single particle mode”, i.e. counting the single particles
hitting the detector at fixed time intervals, ARGO-YBJ can monitor cosmic ray and gamma ray
transients at energies of a few GeV.
The single particle counting rate is modulated by the atmospheric pressure and temperature, and is
affected by the local radioactivity from soil and air. Among the radioactive elements, radon gas is of
particular importance since its concentration in air can vary significantly, according to environmental
conditions. In this paper we evaluate the contribution of the radon daughter gamma ray emitters to the
single particle counting rate measured by ARGO-YBJ. According to our analysis, the radon gas contribution
is roughly 1e2%, producing a counting rate modulation of the same order of magnitude of the
atmospheric effects.
B., B.a., B, ., P., B.c., D, ., X. J., B.e., I., B.n., et al. (2014). Radon contribution to single particle counts of the ARGO-YBJ detector. RADIATION MEASUREMENTS, 68, 42-48 [10.1016/j.radmeas.2014.07.006].
Radon contribution to single particle counts of the ARGO-YBJ detector
B. Bartoli a;b;P. Bernardini c;d;X. J. Bi e;I. Bolognino n;o;P. Branchini f;A. Budano f;P. Camarri g;h;Z. Cao e;R. Cardarelli h;S. Catalanotti a;b;C. Cattaneo o;S. Z. Chen e;T. L. Chen i;P. Creti d;S. W. Cui j;B. Z. Dai k;A. D'Amone c;d;Danzengluobu i;I. De Mitri c;d;B. D'Ettorre Piazzoli a;b;T. Di Girolamo a;b;G. Di Sciascio h;C. F. Feng l;Zhaoyang Feng e;Zhenyong Feng m;E. Giroletti n;o;Q. B. Gou e;Y. Q. Guo e;H. H. He e;Haibing Hu i;Hongbo Hu e;M. Iacovacci a;b;R. Iuppa g;h;H. Y. Jia m;Labaciren i;H. J. Li i;G. Liguori n;o;C. Liu e;J. Liu k;M. Y. Liu i;H. Lu e;L. L. Ma e;X. H. Ma e;G. Mancarella c;d;MARI, Stefano Maria;f, p;G. Marsella c;d;D. Martello c;d;S. Mastroianni b;P. Montini f;p;C. C. Ning i;M. Panareo c;d;L. Perrone c;d;P. Pistilli f;p;F. Ruggieri f;P. Salvini o;R. Santonico g;h;P. R. Shen e;X. D. Sheng e;F. Shi e;A. Surdo d;Y. H. Tan e;P. Vallania q;r;S. Vernetto q;r;C. Vigorito r;s;H. Wang e;C. Y. Wu e;H. R. Wu e;L. Xue l;Q. Y. Yang k;X. C. Yang k;Z. G. Yao e;A. F. Yuan i;M. Zha e;H. M. Zhang e;L. Zhang k;X. Y. Zhang l;Y. Zhang e;J. Zhao e;Zhaxiciren i;Zhaxisangzhu i;X. X. Zhou m;F. R. Zhu m;Q. Q. Zhu e;G. Zizzi t;The ARGO YBJ Collaboration
2014-01-01
Abstract
The ARGO-YBJ experiment is an air shower detector for gamma ray astronomy and cosmic ray studies
with an energy threshold of ~500 GeV. Working in “single particle mode”, i.e. counting the single particles
hitting the detector at fixed time intervals, ARGO-YBJ can monitor cosmic ray and gamma ray
transients at energies of a few GeV.
The single particle counting rate is modulated by the atmospheric pressure and temperature, and is
affected by the local radioactivity from soil and air. Among the radioactive elements, radon gas is of
particular importance since its concentration in air can vary significantly, according to environmental
conditions. In this paper we evaluate the contribution of the radon daughter gamma ray emitters to the
single particle counting rate measured by ARGO-YBJ. According to our analysis, the radon gas contribution
is roughly 1e2%, producing a counting rate modulation of the same order of magnitude of the
atmospheric effects.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/119753
Citazioni
ND
2
2
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.