The ARGO-YBJ experiment has been designed to study the extensive air showers with an energy threshold lower than that of the existing arrays by exploiting the high altitude location (4300 m a.s.l. in Tibet, PR China) and the full ground plane coverage. The lower energy limit of the detector (E similar to 1 GeV) is reached by the scaler mode technique, i.e. recording the counting rate at fixed time intervals. At these energies, transient signals due to local (e.g. Forbush decreases) and cosmological (e.g. Gamma ray bursts) phenomena are expected as a significant variation of the counting rate compared to the background. In this paper, the performance of the ARGO-YBJ detector operating in scaler mode is described and discussed. (C) 2008 Elsevier B.V. All rights reserved.

Aielli, G., Bacci, C., Barone, F., Bartoli, B., Bernardini, P., Bi, X.j., et al. (2008). Scaler mode technique for the ARGO-YBJ detector. ASTROPARTICLE PHYSICS, 30(2), 85-95 [10.1016/j.astropartphys.2008.07.002].

Scaler mode technique for the ARGO-YBJ detector

Bacci C
Membro del Collaboration Group
;
Bussino S
Membro del Collaboration Group
;
Celio P
Membro del Collaboration Group
;
De Vincenzi M
Membro del Collaboration Group
;
Gargana R
Membro del Collaboration Group
;
James I
Membro del Collaboration Group
;
Mari SM
Membro del Collaboration Group
;
Pistilli P
Membro del Collaboration Group
;
Ruggieri F
Membro del Collaboration Group
;
Stanescu C
Membro del Collaboration Group
;
2008-01-01

Abstract

The ARGO-YBJ experiment has been designed to study the extensive air showers with an energy threshold lower than that of the existing arrays by exploiting the high altitude location (4300 m a.s.l. in Tibet, PR China) and the full ground plane coverage. The lower energy limit of the detector (E similar to 1 GeV) is reached by the scaler mode technique, i.e. recording the counting rate at fixed time intervals. At these energies, transient signals due to local (e.g. Forbush decreases) and cosmological (e.g. Gamma ray bursts) phenomena are expected as a significant variation of the counting rate compared to the background. In this paper, the performance of the ARGO-YBJ detector operating in scaler mode is described and discussed. (C) 2008 Elsevier B.V. All rights reserved.
2008
Aielli, G., Bacci, C., Barone, F., Bartoli, B., Bernardini, P., Bi, X.j., et al. (2008). Scaler mode technique for the ARGO-YBJ detector. ASTROPARTICLE PHYSICS, 30(2), 85-95 [10.1016/j.astropartphys.2008.07.002].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/121999
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 70
  • ???jsp.display-item.citation.isi??? 47
social impact