A prototype of the high-sampling lead-scintillating fiber KLOE calorimeter has been exposed to neutron beams of 21, 46 and 174 MeV, provided by the The Svedberg Laboratory, Uppsala, to test its neutron detection efficiency. The measurement of the neutron detection efficiency of an NE110 scintillator provided a reference calibration. The measured efficiency is larger than what expected considering the scintillator thickness of the KLOE prototype only. This result proves the existence of a contribution from the passive material to neutron detection efficiency, in a high-sampling calorimeter configuration. (c) 2008 Elsevier B.V. All rights reserved. RI Gauzzi, Paolo/D-2615-2009; Fiore, Salvatore/C-9722-2011; Di Domenico, Antonio/G-6301-2011; branchini, paolo/A-4857-2011; Battistoni, Giuseppe/B-5264-2012

DI MICCO, B. (2009). Measurement of the detection efficiency of the KLOE calorimeter for neutrons between 22 and 174 MeV. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 598(1), 244-247 [10.1016/j.nima.2008.08.120].

Measurement of the detection efficiency of the KLOE calorimeter for neutrons between 22 and 174 MeV

DI MICCO, Biagio
2009-01-01

Abstract

A prototype of the high-sampling lead-scintillating fiber KLOE calorimeter has been exposed to neutron beams of 21, 46 and 174 MeV, provided by the The Svedberg Laboratory, Uppsala, to test its neutron detection efficiency. The measurement of the neutron detection efficiency of an NE110 scintillator provided a reference calibration. The measured efficiency is larger than what expected considering the scintillator thickness of the KLOE prototype only. This result proves the existence of a contribution from the passive material to neutron detection efficiency, in a high-sampling calorimeter configuration. (c) 2008 Elsevier B.V. All rights reserved. RI Gauzzi, Paolo/D-2615-2009; Fiore, Salvatore/C-9722-2011; Di Domenico, Antonio/G-6301-2011; branchini, paolo/A-4857-2011; Battistoni, Giuseppe/B-5264-2012
2009
DI MICCO, B. (2009). Measurement of the detection efficiency of the KLOE calorimeter for neutrons between 22 and 174 MeV. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 598(1), 244-247 [10.1016/j.nima.2008.08.120].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/122072
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0