The first Barrel Inner Large chamber of the Monitored Drift Tube (MDT) tracking detector for the muon spectrometer of the ATLAS experiment has been tested with a high-energy muon beam. After a description of the MDT characteristics, we present the test beam experimental set-up, the data analysis techniques and discuss the results. The chamber was operated with a Ar(93%)-CO2(7%) gas mixture at 3-bar pressure. The performance studies include the chamber calibration, the single-tube resolution, efficiency and electronic noise, and their behaviour as a function of the high-voltage setting and discriminator threshold. (C) 2003 Elsevier B.V. All rights reserved.

Avolio, G., Bagnaia, P., Baroncelli, A., Beretta, M., Bini, C., Branchini, P., et al. (2004). Test of the first BIL tracking chamber for the ATLAS muon spectrometer. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 523(3), 309-322 [10.1016/j.nima.2003.11.425].

Test of the first BIL tracking chamber for the ATLAS muon spectrometer

PETRUCCI, FABRIZIO;
2004-01-01

Abstract

The first Barrel Inner Large chamber of the Monitored Drift Tube (MDT) tracking detector for the muon spectrometer of the ATLAS experiment has been tested with a high-energy muon beam. After a description of the MDT characteristics, we present the test beam experimental set-up, the data analysis techniques and discuss the results. The chamber was operated with a Ar(93%)-CO2(7%) gas mixture at 3-bar pressure. The performance studies include the chamber calibration, the single-tube resolution, efficiency and electronic noise, and their behaviour as a function of the high-voltage setting and discriminator threshold. (C) 2003 Elsevier B.V. All rights reserved.
2004
Avolio, G., Bagnaia, P., Baroncelli, A., Beretta, M., Bini, C., Branchini, P., et al. (2004). Test of the first BIL tracking chamber for the ATLAS muon spectrometer. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 523(3), 309-322 [10.1016/j.nima.2003.11.425].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/124486
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 24
social impact