A batch of electrolysis cells was developed for tritium in water samples enrichment by at least a factor 10. The cell batch is controlled by a pre-programmable electronic system that interrupts the current through any cell when the planned electrolyte volume is attained. A starting and a final distillation of water samples are carried out before and after the electrolytic enrichment. Both distillations are made to dryness in order to avoid isotopic fractionation. A second electrolysis step allowed the tritium enrichment factor (EFT) to be doubled. The EFT was calculated by means of the deuterium enrichment factor (EFD) that was measured by mass spectrometry. The EFT was also measured by liquid scintillation counting. The calculated and measured EFT values were found in good agreement, especially for samples with significant tritium content. (c) 2006 Elsevier Ltd. All rights reserved.

Plastino, W., Chereji, I., Cuna, S., Kaihola, L., De Felice, P., Lupsa, N., et al. (2007). Tritium in water electrolytic enrichment and liquid scintillation counting RID C-4186-2011. RADIATION MEASUREMENTS, 42(1), 68-73 [10.1016/j.radmeas.2006.07.010].

Tritium in water electrolytic enrichment and liquid scintillation counting RID C-4186-2011

PLASTINO, Wolfango;
2007-01-01

Abstract

A batch of electrolysis cells was developed for tritium in water samples enrichment by at least a factor 10. The cell batch is controlled by a pre-programmable electronic system that interrupts the current through any cell when the planned electrolyte volume is attained. A starting and a final distillation of water samples are carried out before and after the electrolytic enrichment. Both distillations are made to dryness in order to avoid isotopic fractionation. A second electrolysis step allowed the tritium enrichment factor (EFT) to be doubled. The EFT was calculated by means of the deuterium enrichment factor (EFD) that was measured by mass spectrometry. The EFT was also measured by liquid scintillation counting. The calculated and measured EFT values were found in good agreement, especially for samples with significant tritium content. (c) 2006 Elsevier Ltd. All rights reserved.
2007
Plastino, W., Chereji, I., Cuna, S., Kaihola, L., De Felice, P., Lupsa, N., et al. (2007). Tritium in water electrolytic enrichment and liquid scintillation counting RID C-4186-2011. RADIATION MEASUREMENTS, 42(1), 68-73 [10.1016/j.radmeas.2006.07.010].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/124575
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 46
  • ???jsp.display-item.citation.isi??? 45
social impact