Thermal losses for a buried vertical thin plate can be expressed as a function of the assigned temperature distribution, the medium conductivity and the geometrical properties that describe the model. When the geometrical properties reduce to one, the plate-ground thermal resistance can be expressed regardless of plate dimension, depending only on temperature distribution given at surface plate and its temperature difference with medium.

FONTANA L, & QUINTINO A. (2009). Heat loss from buried vertical plate with assigned temperature distribution. JOURNAL OF THERMAL SCIENCE, 18(3), 253-255 [10.1007/s11630-009-0253-8].

Heat loss from buried vertical plate with assigned temperature distribution

FONTANA, Lucia;
2009

Abstract

Thermal losses for a buried vertical thin plate can be expressed as a function of the assigned temperature distribution, the medium conductivity and the geometrical properties that describe the model. When the geometrical properties reduce to one, the plate-ground thermal resistance can be expressed regardless of plate dimension, depending only on temperature distribution given at surface plate and its temperature difference with medium.
File in questo prodotto: