The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data-taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and in-situ calibrations are described. Tracking performance has been measured with 7.6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energy-loss calibration and transition radiation turn-on measurements have been performed. Different alignment techniques have been used to reconstruct the detector geometry. After the initial alignment, a transverse impact parameter resolution of 22.1 +/- 0.9 mu m and a relative momentum resolution sigma (p) /p=(4.83 +/- 0.16)x10(-4) GeV(-1)xp (T) have been measured for high momentum tracks.

Aad, G., Abbott, B., Abdallah, J., Abdelalim, A.a., Abdesselam, A., Abdinov, O., et al. (2010). The ATLAS Inner Detector commissioning and calibration. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 70(3), 787-821 [10.1140/epjc/s10052-010-1366-7].

The ATLAS Inner Detector commissioning and calibration

CERADINI, Filippo;Di Nardo R;Orestano D;PETRUCCI, FABRIZIO;Ruggieri F;SALAMANNA, GIUSEPPE;
2010-01-01

Abstract

The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data-taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and in-situ calibrations are described. Tracking performance has been measured with 7.6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energy-loss calibration and transition radiation turn-on measurements have been performed. Different alignment techniques have been used to reconstruct the detector geometry. After the initial alignment, a transverse impact parameter resolution of 22.1 +/- 0.9 mu m and a relative momentum resolution sigma (p) /p=(4.83 +/- 0.16)x10(-4) GeV(-1)xp (T) have been measured for high momentum tracks.
2010
Aad, G., Abbott, B., Abdallah, J., Abdelalim, A.a., Abdesselam, A., Abdinov, O., et al. (2010). The ATLAS Inner Detector commissioning and calibration. THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 70(3), 787-821 [10.1140/epjc/s10052-010-1366-7].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/131913
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 86
  • ???jsp.display-item.citation.isi??? 75
social impact