In this paper we document the results of the study which led to the ripple correction and absolute calibration algorithms applied to the high resolution spectra processed with the NEWSIPS software for the Final archive of the IUE Project. In this analysis, based on a very large number of spectral we find that both the It and alpha parameters (not only the former as previously believed) vary with order number. This fact, together with the finding that the central peaks of the blaze function vary also as a function of the THDA temperature (for the SWP camera) and of the date of observations (for the LWP and LWR cameras), makes the ripple correction algorithm more complex than previously considered but, at the same time, considerably more reliable. As for the high resolution absolute calibration, the method followed is similar to the one implemented in IUESIPS. The internal accuracy of the high resolution calibration is about 4%. We note that the ripple correction and absolute calibration algorithms here described apply also to IUE data processed and distributed with the INES system.

Cassatella, A., Altamore, A., Gonzalez Riestra, R., Ponz, J.d., Barbero, J., Talavera, A., et al. (2000). The INES system - II. Ripple correction and absolute calibration for IUE high resolution spectra. ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 141(2), 331-341 [10.1051/aas:2000316].

The INES system - II. Ripple correction and absolute calibration for IUE high resolution spectra

ALTAMORE, Aldo;
2000-01-01

Abstract

In this paper we document the results of the study which led to the ripple correction and absolute calibration algorithms applied to the high resolution spectra processed with the NEWSIPS software for the Final archive of the IUE Project. In this analysis, based on a very large number of spectral we find that both the It and alpha parameters (not only the former as previously believed) vary with order number. This fact, together with the finding that the central peaks of the blaze function vary also as a function of the THDA temperature (for the SWP camera) and of the date of observations (for the LWP and LWR cameras), makes the ripple correction algorithm more complex than previously considered but, at the same time, considerably more reliable. As for the high resolution absolute calibration, the method followed is similar to the one implemented in IUESIPS. The internal accuracy of the high resolution calibration is about 4%. We note that the ripple correction and absolute calibration algorithms here described apply also to IUE data processed and distributed with the INES system.
2000
Cassatella, A., Altamore, A., Gonzalez Riestra, R., Ponz, J.d., Barbero, J., Talavera, A., et al. (2000). The INES system - II. Ripple correction and absolute calibration for IUE high resolution spectra. ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 141(2), 331-341 [10.1051/aas:2000316].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/141371
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 22
social impact