Pulmonary ventilators for intensive care provide information on, among many other patient respiratory parameters, patient resistance, compliance and ‘work of breathing’ values calculated from pressure and flow data patterns according to a widely utilized algorithm. The effects induced by the breathing circuit and analogue filtering of the ventilator measuring system are experimentally investigated during controlled ventilation. Three main phenomena are observed: (a) errors in calculation of resistance and compliance due to filtering of pressure and flow waveforms; (b) the presence of pressure oscillations at the beginning of inspiration and expiration phases; and (c) the phase shift between pressure and flow waveforms. The experimental evaluation of the measuring system of a neonatal ventilator is then conducted and: (a) a delay in pressure and flow measurement synchronization equal to 22+2 ms is evaluated; moreover, (b) a difference between the values provided by the ventilator and those measured by the reference experimental setup on respiratory parameters such as the compliance, resistance and work of breathing that lies in the range of 7 – 16% of reading is observed.

Cappa, P., Sciuto, S.A., Silvestri, S. (2006). Experimental evaluation of errors in the measurement of respiratory parameters of the newborn performed by a continuous flow neonatal ventilator. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 30-1, 31-40 [10.1080/03091900500040295.].

Experimental evaluation of errors in the measurement of respiratory parameters of the newborn performed by a continuous flow neonatal ventilator

SCIUTO, SALVATORE ANDREA;
2006-01-01

Abstract

Pulmonary ventilators for intensive care provide information on, among many other patient respiratory parameters, patient resistance, compliance and ‘work of breathing’ values calculated from pressure and flow data patterns according to a widely utilized algorithm. The effects induced by the breathing circuit and analogue filtering of the ventilator measuring system are experimentally investigated during controlled ventilation. Three main phenomena are observed: (a) errors in calculation of resistance and compliance due to filtering of pressure and flow waveforms; (b) the presence of pressure oscillations at the beginning of inspiration and expiration phases; and (c) the phase shift between pressure and flow waveforms. The experimental evaluation of the measuring system of a neonatal ventilator is then conducted and: (a) a delay in pressure and flow measurement synchronization equal to 22+2 ms is evaluated; moreover, (b) a difference between the values provided by the ventilator and those measured by the reference experimental setup on respiratory parameters such as the compliance, resistance and work of breathing that lies in the range of 7 – 16% of reading is observed.
2006
Cappa, P., Sciuto, S.A., Silvestri, S. (2006). Experimental evaluation of errors in the measurement of respiratory parameters of the newborn performed by a continuous flow neonatal ventilator. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 30-1, 31-40 [10.1080/03091900500040295.].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/146412
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 22
  • ???jsp.display-item.citation.isi??? ND
social impact