Many of the physics processes of interest at the Large Hadron Collider (LHC) will involve muon production in the final state. The Monitored Drift Tube (MDT) chambers, the precision tracking elements of the ATLAS muon spectrometer, are the main tools for the muon identification and measurement. They will operate in the harsh LHC background environment, mainly due to low energy photons and neutrons which will dominate the counting rate in most areas of the spectrometer, where an overall maximum counting rate of 500 Hz/cm(2) is expected. The upgrade to Super-LHC will involve fluxes ten times higher. To study the behaviour of MDT chambers under massive neutron irradiation at the level of Super-LHC, a test was performed at the "Tapiro" Neutron Facility of the ENEA "La Casaccia" Research Center

Branchini, P., Petrucci, F. (2007). ATLAS MDT chamber behaviour after neutron irradiation and in a high rate background. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 581(1-2), 171-174 [10.1016/j.nima.2007.07.071].

ATLAS MDT chamber behaviour after neutron irradiation and in a high rate background

PETRUCCI, FABRIZIO
2007-01-01

Abstract

Many of the physics processes of interest at the Large Hadron Collider (LHC) will involve muon production in the final state. The Monitored Drift Tube (MDT) chambers, the precision tracking elements of the ATLAS muon spectrometer, are the main tools for the muon identification and measurement. They will operate in the harsh LHC background environment, mainly due to low energy photons and neutrons which will dominate the counting rate in most areas of the spectrometer, where an overall maximum counting rate of 500 Hz/cm(2) is expected. The upgrade to Super-LHC will involve fluxes ten times higher. To study the behaviour of MDT chambers under massive neutron irradiation at the level of Super-LHC, a test was performed at the "Tapiro" Neutron Facility of the ENEA "La Casaccia" Research Center
2007
Branchini, P., Petrucci, F. (2007). ATLAS MDT chamber behaviour after neutron irradiation and in a high rate background. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 581(1-2), 171-174 [10.1016/j.nima.2007.07.071].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/149229
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact