The aim of this work is to investigate the possibility of extracting correct structural parameters from fluorescence EXAFS data taken at high count rates with an energy-resolving detector. This situation is often encountered on third-generation synchrotron radiation sources which provide a high flux on the sample. Errors caused by pulse pile-up in the extraction of structural information have been quantified in a real experiment, and different approaches to the problem of data correction have been elaborated. The different approaches are discussed in a comparison of the ability of each kind of correction to recover the correct structural parameters. The result of our analysis is that it is possible to work in non-linear conditions and correct the data, if the response of the acquisition system is known. Reliable structural information can be obtained with data acquired up to a count rate equal to approximately 60% of the inverse of the dead time.

Ciatto, G., D'Acapito, F., Boscherini, F., Mobilio, ., Mobilio, S. (2004). Treatment of EXAFS data taken in the fluorescence mode in non-linear conditions. JOURNAL OF SYNCHROTRON RADIATION, 11, 278-283 [10.1107/S0909049504002122].

Treatment of EXAFS data taken in the fluorescence mode in non-linear conditions

MOBILIO, Settimio
2004-01-01

Abstract

The aim of this work is to investigate the possibility of extracting correct structural parameters from fluorescence EXAFS data taken at high count rates with an energy-resolving detector. This situation is often encountered on third-generation synchrotron radiation sources which provide a high flux on the sample. Errors caused by pulse pile-up in the extraction of structural information have been quantified in a real experiment, and different approaches to the problem of data correction have been elaborated. The different approaches are discussed in a comparison of the ability of each kind of correction to recover the correct structural parameters. The result of our analysis is that it is possible to work in non-linear conditions and correct the data, if the response of the acquisition system is known. Reliable structural information can be obtained with data acquired up to a count rate equal to approximately 60% of the inverse of the dead time.
2004
Ciatto, G., D'Acapito, F., Boscherini, F., Mobilio, ., Mobilio, S. (2004). Treatment of EXAFS data taken in the fluorescence mode in non-linear conditions. JOURNAL OF SYNCHROTRON RADIATION, 11, 278-283 [10.1107/S0909049504002122].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/151105
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 48
social impact