An electronic speckle pattern interferometric system combined with an endoscopic probe capable of measuring the diffusion coefficient of fluid mixtures as a function of temperature is presented. Its use for an aqueous solution LiBr is considered as an example in the temperature range 298–333 K

Paoletti, D., SCHIRRIPA SPAGNOLO, G. (1997). Temperature dependence of fluid mixtures diffusivity by ESPI endoscopy. OPTICS AND LASERS IN ENGINEERING, 26, 301-312 [10.1016/0143-8166(95)00135-2].

Temperature dependence of fluid mixtures diffusivity by ESPI endoscopy

SCHIRRIPA SPAGNOLO, Giuseppe
1997-01-01

Abstract

An electronic speckle pattern interferometric system combined with an endoscopic probe capable of measuring the diffusion coefficient of fluid mixtures as a function of temperature is presented. Its use for an aqueous solution LiBr is considered as an example in the temperature range 298–333 K
1997
Paoletti, D., SCHIRRIPA SPAGNOLO, G. (1997). Temperature dependence of fluid mixtures diffusivity by ESPI endoscopy. OPTICS AND LASERS IN ENGINEERING, 26, 301-312 [10.1016/0143-8166(95)00135-2].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/155673
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 12
social impact