Ultrasound (US) has become increasingly important in imaging and image-guided interventional procedures. In order to ensure that the imaging equipment performs to the highest level achievable and thus provides reliable clinical results, a number of quality control (QC) methods have been developed. Such QC is increasingly required by accrediting agencies and professional organizations; however, these requirements typically do not include detailed procedures for how the tests should be performed. In this paper, a detailed overview of QC methods for general and breast US imaging using computer-based objective methods is described. The application of QC is then discussed within the context of a common clinical application (US-guided needle biopsy) as well as for research applications, where QC may not be mandated, and thus is rarely discussed. The implementation of these methods will help in finding early stage equipment faults and in optimizing image quality, which could lead to better detection and classification of suspicious findings in clinical applications, as well as improving the robustness of research studies.

Sassaroli, E., Scorza, A., Crake, C., Sciuto, S.A., Park, M.A. (2017). Breast ultrasound technology and performance evaluation of ultrasound equipment: B-mode. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 64(1), 192-205 [10.1109/TUFFC.2016.2619622].

Breast ultrasound technology and performance evaluation of ultrasound equipment: B-mode

SCORZA, ANDREA
Membro del Collaboration Group
;
SCIUTO, SALVATORE ANDREA
Supervision
;
2017-01-01

Abstract

Ultrasound (US) has become increasingly important in imaging and image-guided interventional procedures. In order to ensure that the imaging equipment performs to the highest level achievable and thus provides reliable clinical results, a number of quality control (QC) methods have been developed. Such QC is increasingly required by accrediting agencies and professional organizations; however, these requirements typically do not include detailed procedures for how the tests should be performed. In this paper, a detailed overview of QC methods for general and breast US imaging using computer-based objective methods is described. The application of QC is then discussed within the context of a common clinical application (US-guided needle biopsy) as well as for research applications, where QC may not be mandated, and thus is rarely discussed. The implementation of these methods will help in finding early stage equipment faults and in optimizing image quality, which could lead to better detection and classification of suspicious findings in clinical applications, as well as improving the robustness of research studies.
2017
Sassaroli, E., Scorza, A., Crake, C., Sciuto, S.A., Park, M.A. (2017). Breast ultrasound technology and performance evaluation of ultrasound equipment: B-mode. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 64(1), 192-205 [10.1109/TUFFC.2016.2619622].
File in questo prodotto:
File Dimensione Formato  
Breast Ultrasound Technology and Performance_2016_post-print.pdf

accesso aperto

Descrizione: Articolo in versione post-print
Tipologia: Documento in Post-print
Licenza: DRM non definito
Dimensione 1.1 MB
Formato Adobe PDF
1.1 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/317073
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 7
social impact