Masonry vaults can be particularly vulnerable against unsymmetrical service loads, support displacements and seismic actions. Retrofitting is often needed to ensure an adequate safety level according to current standard codes. Externally bonded composites are emerging as a possible retrofitting technique, but no experimental evidence is still available on the response of reinforced vaults reinforced taking into account the contribution of buttresses and backfill. This paper describes an experimental investigation on four full-scale vault specimens. One of them was tested unreinforced, whereas the other ones were strengthened with Steel Reinforced Grout (SRG), comprising ultra high tensile strength steel cords, bonded with lime-based mortar either to the extrados or to the intrados. The vaults were subjected to cyclic loading at 1/3 span. The backfill was visible through a panel of Plexiglas, allowing for the use of Digital Image Correlation to measure the displacement field and derive information on damage pattern and arch-fill interaction. Tests showed that SRG prevented the development of the four-hinge mechanism and avoided damage concentrations, increasing the deflection capacity and the strength of the arch by 2–3 times. Finally, it is shown that a simplified analytical approach based on limit analysis provides a reliable estimate of experimental load carrying capacity.

DE SANTIS, S., Roscini, F., DE FELICE, G. (2018). Full-scale tests on masonry vaults strengthened with Steel Reinforced Grout. COMPOSITES. PART B, ENGINEERING, 141, 20-36 [10.1016/j.compositesb.2017.12.023].

Full-scale tests on masonry vaults strengthened with Steel Reinforced Grout

Stefano De Santis
;
Francesca Roscini;Gianmarco de Felice
2018-01-01

Abstract

Masonry vaults can be particularly vulnerable against unsymmetrical service loads, support displacements and seismic actions. Retrofitting is often needed to ensure an adequate safety level according to current standard codes. Externally bonded composites are emerging as a possible retrofitting technique, but no experimental evidence is still available on the response of reinforced vaults reinforced taking into account the contribution of buttresses and backfill. This paper describes an experimental investigation on four full-scale vault specimens. One of them was tested unreinforced, whereas the other ones were strengthened with Steel Reinforced Grout (SRG), comprising ultra high tensile strength steel cords, bonded with lime-based mortar either to the extrados or to the intrados. The vaults were subjected to cyclic loading at 1/3 span. The backfill was visible through a panel of Plexiglas, allowing for the use of Digital Image Correlation to measure the displacement field and derive information on damage pattern and arch-fill interaction. Tests showed that SRG prevented the development of the four-hinge mechanism and avoided damage concentrations, increasing the deflection capacity and the strength of the arch by 2–3 times. Finally, it is shown that a simplified analytical approach based on limit analysis provides a reliable estimate of experimental load carrying capacity.
2018
DE SANTIS, S., Roscini, F., DE FELICE, G. (2018). Full-scale tests on masonry vaults strengthened with Steel Reinforced Grout. COMPOSITES. PART B, ENGINEERING, 141, 20-36 [10.1016/j.compositesb.2017.12.023].
File in questo prodotto:
File Dimensione Formato  
DeSantisetal_2018_arches.pdf

accesso aperto

Tipologia: Documento in Pre-print
Licenza: DRM non definito
Dimensione 6.14 MB
Formato Adobe PDF
6.14 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/326664
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 60
  • ???jsp.display-item.citation.isi??? 43
social impact