This paper focuses on the investigation and implementation of a high-performance power conversion system to reduce the overvoltage phenomenon in variable speed electric drive applications. Particularly, the pros and cons of using Silicon Carbide power MOSFETs in the power converter when a long power cable is employed in electric motor drive systems has been addressed. The three-phase two level inverter with the addition of snubber circuits that consist of capacitors and diodes has been investigated, designed and tested in order to mitigate the overvoltage problems without sacrificing the conversion efficiency. Given that the snubber circuit added to the switches can increase losses, an additional circuit is used to recover the energy from the snubber circuit. The proposed analysis has been then validated through an experimental campaign performed on the converter prototype. The experimental results show that the proposed converter can reduce the overvoltage at the electric motor terminals with excellent conversion efficiency compared to the classical solution like the three-phase two level inverter.
di Benedetto, M., Bigarelli, L., Lidozzi, A., Solero, L. (2021). Efficiency Comparison of 2-Level SiC Inverter and Soft Switching-Snubber SiC Inverter for Electric Motor Drives. ENERGIES, 14(6), 1690 [10.3390/en14061690].
Efficiency Comparison of 2-Level SiC Inverter and Soft Switching-Snubber SiC Inverter for Electric Motor Drives
di Benedetto, Marco;Bigarelli, Luca;Lidozzi, Alessandro;Solero, Luca
2021-01-01
Abstract
This paper focuses on the investigation and implementation of a high-performance power conversion system to reduce the overvoltage phenomenon in variable speed electric drive applications. Particularly, the pros and cons of using Silicon Carbide power MOSFETs in the power converter when a long power cable is employed in electric motor drive systems has been addressed. The three-phase two level inverter with the addition of snubber circuits that consist of capacitors and diodes has been investigated, designed and tested in order to mitigate the overvoltage problems without sacrificing the conversion efficiency. Given that the snubber circuit added to the switches can increase losses, an additional circuit is used to recover the energy from the snubber circuit. The proposed analysis has been then validated through an experimental campaign performed on the converter prototype. The experimental results show that the proposed converter can reduce the overvoltage at the electric motor terminals with excellent conversion efficiency compared to the classical solution like the three-phase two level inverter.File | Dimensione | Formato | |
---|---|---|---|
energies-14-01690.pdf
accesso aperto
Tipologia:
Documento in Post-print
Licenza:
DRM non definito
Dimensione
7.3 MB
Formato
Adobe PDF
|
7.3 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.