This paper presents the results of a numerical study aimed to investigate the seismic behaviour of mixed multistorey wood buildings made of CLT and Light-Frame shear walls acting at the same level. Eurocode 8 provides little information on the seismic design of buildings with different lateral load resisting systems working at the same level. A suggestion is given to perform non-linear static or non-linear dynamic analysis to design the structure. The application of linear analysis methods using the force-based procedure is not possible since the value of the behaviour factor q of the mixed system is unknown. The aim of this investigation is to propose a simple analytical formulation to estimate the value of the q-factor of the mixed system, so as to enable the use of the force-based philosophy of Eurocode 8 for the seismic design of mixed CLT/Light-Frame buildings. This was achieved by analysing the results of non-linear dynamic (time-history) analyses performed on a four-storey casestudy building with different combinations of CLT and Light-Frame shear walls. Finally, the validity of the proposed formulation is checked by means of non-linear dynamic (time-history) analyses performed on the same four storey case-study building in one of the hybrid combinations of CLT and Light-Frame shear walls.
Follesa, M., Fragiacomo, M. (2018). Force-based seismic design of mixed CLT/Light-Frame buildings. ENGINEERING STRUCTURES, 168, 628-642 [10.1016/j.engstruct.2018.04.091].
Force-based seismic design of mixed CLT/Light-Frame buildings
M. Follesa;M. Fragiacomo
2018-01-01
Abstract
This paper presents the results of a numerical study aimed to investigate the seismic behaviour of mixed multistorey wood buildings made of CLT and Light-Frame shear walls acting at the same level. Eurocode 8 provides little information on the seismic design of buildings with different lateral load resisting systems working at the same level. A suggestion is given to perform non-linear static or non-linear dynamic analysis to design the structure. The application of linear analysis methods using the force-based procedure is not possible since the value of the behaviour factor q of the mixed system is unknown. The aim of this investigation is to propose a simple analytical formulation to estimate the value of the q-factor of the mixed system, so as to enable the use of the force-based philosophy of Eurocode 8 for the seismic design of mixed CLT/Light-Frame buildings. This was achieved by analysing the results of non-linear dynamic (time-history) analyses performed on a four-storey casestudy building with different combinations of CLT and Light-Frame shear walls. Finally, the validity of the proposed formulation is checked by means of non-linear dynamic (time-history) analyses performed on the same four storey case-study building in one of the hybrid combinations of CLT and Light-Frame shear walls.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.