A model-scale experimental investigation of an installed jet-pylon-wing configuration was conducted at the University of Southampton, with the scope to study the effect a pylon has on noise generation and to clarify its impact on the fluctuating wall-pressure load. The set-up consisted of two single-stream nozzles, a baseline axisymmetric annular nozzle and a partially blocked annular pylon nozzle. The nozzles were tested first isolated and then installed next to a NACA4415 aerofoil 'wing' at a single nozzle-wing position. The jet Mach number was varied between and measurements were performed both under static and in-flight ambient flow conditions up to. The jet flow-field qualification was carried out using a single-velocity-component hot-wire anemometer probe. The pressure field on the wing surface was investigated using two miniature wall-pressure transducers that were flush-mounted in the streamwise and spanwise directions within the pressure side of the wing. A linear 'flyover' microphone array was used to record the noise radiated to the far field. The unsteady pressure data were analysed in both time and frequency domains using multi-variate statistics, highlighting a far-field noise reduction provided by the presence of the pylon only in the installed case. Furthermore, the wake field generated behind the pylon is seen to significantly modify the wall-pressure fluctuations, particularly at streamwise locations close to the pylon trailing edge.
Meloni, S., Proenca, A.R., Lawrence, J.L.T., Camussi, R. (2021). An experimental investigation into model-scale installed jet-pylon-wing noise. JOURNAL OF FLUID MECHANICS, 929 [10.1017/jfm.2021.831].
An experimental investigation into model-scale installed jet-pylon-wing noise
Meloni S.
;Camussi R.
2021-01-01
Abstract
A model-scale experimental investigation of an installed jet-pylon-wing configuration was conducted at the University of Southampton, with the scope to study the effect a pylon has on noise generation and to clarify its impact on the fluctuating wall-pressure load. The set-up consisted of two single-stream nozzles, a baseline axisymmetric annular nozzle and a partially blocked annular pylon nozzle. The nozzles were tested first isolated and then installed next to a NACA4415 aerofoil 'wing' at a single nozzle-wing position. The jet Mach number was varied between and measurements were performed both under static and in-flight ambient flow conditions up to. The jet flow-field qualification was carried out using a single-velocity-component hot-wire anemometer probe. The pressure field on the wing surface was investigated using two miniature wall-pressure transducers that were flush-mounted in the streamwise and spanwise directions within the pressure side of the wing. A linear 'flyover' microphone array was used to record the noise radiated to the far field. The unsteady pressure data were analysed in both time and frequency domains using multi-variate statistics, highlighting a far-field noise reduction provided by the presence of the pylon only in the installed case. Furthermore, the wake field generated behind the pylon is seen to significantly modify the wall-pressure fluctuations, particularly at streamwise locations close to the pylon trailing edge.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.