Indoor radon surveying and remediation were implemented in a single-family home affected by high levels of indoor radon in the Celleno municipality (central Italy) with the aim of identifying the contribution of radon sources, evaluating the factors affecting radon entry into the building, and reducing radon risk. Average radon levels were relatively low at the ground floor (286 ± 202 Bq m−3) and first floor (167 ± 84 Bq m−3) in autumn when the temperature was still warm and the windows were open, but increased up to 2776 ± 1768 Bq m−3 and 970 ± 202 Bq m−3 in the first half of December, when the heating system was on and the windows were closed. The inner walls of the pilot room at the ground floor, semi buried on one side, were then treated with a waterproof product (a silane terminated polymer) and the average radon was halved (1475 ± 1092 Bq m−3) in the following month, which was still characterised by winter conditions. Radon entry in the room was identified and sealed with the same product, and a radon accumulation space behind a NE-SW oriented wall was naturally ventilated, reducing radon below the reference level in April with northerly winds conditions.

Portaro, M., Rocchetti, I., Tuccimei, P., Galli, G., Soligo, M., Ciotoli, G., et al. (2024). Indoor Radon Surveying and Mitigation in the Case-Study of Celleno Town (Central Italy) Located in a Medium Geogenic Radon Potential Area. ATMOSPHERE, 15(4) [10.3390/atmos15040425].

Indoor Radon Surveying and Mitigation in the Case-Study of Celleno Town (Central Italy) Located in a Medium Geogenic Radon Potential Area

Portaro M.;Rocchetti I.;Tuccimei P.;Soligo M.;Sola F.
2024-01-01

Abstract

Indoor radon surveying and remediation were implemented in a single-family home affected by high levels of indoor radon in the Celleno municipality (central Italy) with the aim of identifying the contribution of radon sources, evaluating the factors affecting radon entry into the building, and reducing radon risk. Average radon levels were relatively low at the ground floor (286 ± 202 Bq m−3) and first floor (167 ± 84 Bq m−3) in autumn when the temperature was still warm and the windows were open, but increased up to 2776 ± 1768 Bq m−3 and 970 ± 202 Bq m−3 in the first half of December, when the heating system was on and the windows were closed. The inner walls of the pilot room at the ground floor, semi buried on one side, were then treated with a waterproof product (a silane terminated polymer) and the average radon was halved (1475 ± 1092 Bq m−3) in the following month, which was still characterised by winter conditions. Radon entry in the room was identified and sealed with the same product, and a radon accumulation space behind a NE-SW oriented wall was naturally ventilated, reducing radon below the reference level in April with northerly winds conditions.
2024
Portaro, M., Rocchetti, I., Tuccimei, P., Galli, G., Soligo, M., Ciotoli, G., et al. (2024). Indoor Radon Surveying and Mitigation in the Case-Study of Celleno Town (Central Italy) Located in a Medium Geogenic Radon Potential Area. ATMOSPHERE, 15(4) [10.3390/atmos15040425].
File in questo prodotto:
File Dimensione Formato  
Atmosphere 2024.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 1.94 MB
Formato Adobe PDF
1.94 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/472527
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact