The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction.

Agnes, P., Albuquerque, I.F.M., Alexander, T., Alton, A.K., Ave, M., Back, H.O., et al. (2024). Long-term temporal stability of the DarkSide-50 dark matter detector. JOURNAL OF INSTRUMENTATION, 19(05) [10.1088/1748-0221/19/05/p05057].

Long-term temporal stability of the DarkSide-50 dark matter detector

Bussino, S.
Membro del Collaboration Group
;
Mari, S. M.
Membro del Collaboration Group
;
Sanfilippo, S.
Membro del Collaboration Group
;
2024-01-01

Abstract

The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction.
2024
Agnes, P., Albuquerque, I.F.M., Alexander, T., Alton, A.K., Ave, M., Back, H.O., et al. (2024). Long-term temporal stability of the DarkSide-50 dark matter detector. JOURNAL OF INSTRUMENTATION, 19(05) [10.1088/1748-0221/19/05/p05057].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/474168
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact