In a cascaded H-bridge (CHB) multilevel inverter, carrier-based pulse width modulation (PWM) schemes are preferred due to ease of computation and implementation. The commonly used level-shifted carrier PWM (LSPWM) introduces extreme disparity in power handled by each module, specifically for CHBs fed by multiple isolated converters from a common dc link. This power imbalance creates asymmetric thermal and electrical stresses leading to premature failures in overstressed modules. One computationally simple solution to this problem is known as first-in-first-out (FIFO) carrier reassignment, which somewhat reduces the power disparity between the modules compared to LSPWM. This article presents a novel carrier-reassignment scheme for nine-level CHB inverters to achieve perfect power balance across the modules. A quadrant-by-quadrant carrier-reassignment scheme is used which results in minimal computational burden. Since the proposed scheme only requires a sampled voltage reference, it can be well integrated into existing inverter control schemes such as dq-control in grid-tied operation. The proposed scheme is first simulated to verify the improved module power balance in a grid-tied configuration. The results are further verified with a hardware prototype operating in grid-connected mode, demonstrating a near-perfect power balance among the modules.
Pradhan, L., Varma, R., Kshirsagar, A., Venkatramanan, D., Benedetto, M.d., Lidozzi, A. (2024). Module Power Equalization Through Carrier-Reassignment PWM in a Nine-Level Cascaded H-Bridge Grid-Tied Inverter. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1-10 [10.1109/TIE.2024.3395752].
Module Power Equalization Through Carrier-Reassignment PWM in a Nine-Level Cascaded H-Bridge Grid-Tied Inverter
Benedetto, Marco di;Lidozzi, Alessandro
2024-01-01
Abstract
In a cascaded H-bridge (CHB) multilevel inverter, carrier-based pulse width modulation (PWM) schemes are preferred due to ease of computation and implementation. The commonly used level-shifted carrier PWM (LSPWM) introduces extreme disparity in power handled by each module, specifically for CHBs fed by multiple isolated converters from a common dc link. This power imbalance creates asymmetric thermal and electrical stresses leading to premature failures in overstressed modules. One computationally simple solution to this problem is known as first-in-first-out (FIFO) carrier reassignment, which somewhat reduces the power disparity between the modules compared to LSPWM. This article presents a novel carrier-reassignment scheme for nine-level CHB inverters to achieve perfect power balance across the modules. A quadrant-by-quadrant carrier-reassignment scheme is used which results in minimal computational burden. Since the proposed scheme only requires a sampled voltage reference, it can be well integrated into existing inverter control schemes such as dq-control in grid-tied operation. The proposed scheme is first simulated to verify the improved module power balance in a grid-tied configuration. The results are further verified with a hardware prototype operating in grid-connected mode, demonstrating a near-perfect power balance among the modules.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.