In this paper different estimation techniques are evaluated for the assessment of electromechanical delay (EMD). The following techniques are compared for benchmarking purposes: envelope estimation and thresholding, with different subjective combinations of filters and thresholds, and a double threshold statistical detector (DTD). Performances are compared in terms of bias, standard deviation and erroneous detections of the estimations. DTD showed higher robustness and repeatability of results, guaranteed by the objective settings based on the statistical characteristics of the algorithm.

In this paper different estimation techniques are evaluated for the assessment of Electromechanical Delay (EMD). The following techniques are compared for benchmarking purposes: envelope estimation and thresholding, with different subjective combinations of filters and thresholds, and a double threshold statistical detector (DTD). Performance are compared in terms of bias, standard deviation and erroneous detections of the estimations. DTD showed higher robustness and repeatability of results, guaranteed by the objective settings based on the statistical characteristics of the algorithm.

Conforto, S., Mathieu, P.a., Schmid, M., Bibbo, D., Florestal, J.r., D'Alessio, T. (2006). How Much Can We Trust the Electromechanical Delay Estimated by Using Electromyography?. In Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings (pp.1256-1259). NEW YORK : IEEE [10.1109/IEMBS.2006.259335].

How Much Can We Trust the Electromechanical Delay Estimated by Using Electromyography?

CONFORTO, SILVIA;SCHMID, Maurizio;BIBBO, DANIELE;
2006-01-01

Abstract

In this paper different estimation techniques are evaluated for the assessment of Electromechanical Delay (EMD). The following techniques are compared for benchmarking purposes: envelope estimation and thresholding, with different subjective combinations of filters and thresholds, and a double threshold statistical detector (DTD). Performance are compared in terms of bias, standard deviation and erroneous detections of the estimations. DTD showed higher robustness and repeatability of results, guaranteed by the objective settings based on the statistical characteristics of the algorithm.
2006
978-1-4244-0032-4
In this paper different estimation techniques are evaluated for the assessment of electromechanical delay (EMD). The following techniques are compared for benchmarking purposes: envelope estimation and thresholding, with different subjective combinations of filters and thresholds, and a double threshold statistical detector (DTD). Performances are compared in terms of bias, standard deviation and erroneous detections of the estimations. DTD showed higher robustness and repeatability of results, guaranteed by the objective settings based on the statistical characteristics of the algorithm.
Conforto, S., Mathieu, P.a., Schmid, M., Bibbo, D., Florestal, J.r., D'Alessio, T. (2006). How Much Can We Trust the Electromechanical Delay Estimated by Using Electromyography?. In Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings (pp.1256-1259). NEW YORK : IEEE [10.1109/IEMBS.2006.259335].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/176074
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 0
social impact