Quality Controls (QCs) for the evaluation of Color Doppler (CD) performance play a pivotal role since CD Is one of the most widely used Doppler techniques in medical imaging. Among the recommended test parameters, directional accuracy at 90° is included, even if its assessment is carried out visually. Therefore, in this study, a novel CD test parameter, called blind angle, has been proposed and defined as it allows testing the Doppler frequency shift dependency on the insonation angle Moreover, a novel automatic method for the estimation of this parameter through the post-processing of CD videos has been proposed. Data have been collected from a single ultrasound diagnostic system equipped with a phased array probe. Tests have been carried out for two probe frequencies and three constant flow rate regimes set on a flow phantom. Based on the preliminary promising outcomes, further studies are going to be carried out.

Fiori, G., Scorza, A., Schmid, M., Galo, J., Conforto, S., Sciuto, S.A. (2022). A preliminary study on the blind angle estimation for Quality Assessment of Color Doppler ultrasound diagnostic systems. In 25th IMEKO TC-4 International Symposium on Measurement of Electrical Quantities, IMEKO TC-4 2022 and 23rd International Workshop on ADC and DAC Modelling and Testing, IWADC 2022 (pp.325-329). International Measurement Confederation (IMEKO).

A preliminary study on the blind angle estimation for Quality Assessment of Color Doppler ultrasound diagnostic systems

Fiori G.
Investigation
;
Scorza A.
Project Administration
;
Schmid M.;Conforto S.;Sciuto S. A.
2022-01-01

Abstract

Quality Controls (QCs) for the evaluation of Color Doppler (CD) performance play a pivotal role since CD Is one of the most widely used Doppler techniques in medical imaging. Among the recommended test parameters, directional accuracy at 90° is included, even if its assessment is carried out visually. Therefore, in this study, a novel CD test parameter, called blind angle, has been proposed and defined as it allows testing the Doppler frequency shift dependency on the insonation angle Moreover, a novel automatic method for the estimation of this parameter through the post-processing of CD videos has been proposed. Data have been collected from a single ultrasound diagnostic system equipped with a phased array probe. Tests have been carried out for two probe frequencies and three constant flow rate regimes set on a flow phantom. Based on the preliminary promising outcomes, further studies are going to be carried out.
2022
Fiori, G., Scorza, A., Schmid, M., Galo, J., Conforto, S., Sciuto, S.A. (2022). A preliminary study on the blind angle estimation for Quality Assessment of Color Doppler ultrasound diagnostic systems. In 25th IMEKO TC-4 International Symposium on Measurement of Electrical Quantities, IMEKO TC-4 2022 and 23rd International Workshop on ADC and DAC Modelling and Testing, IWADC 2022 (pp.325-329). International Measurement Confederation (IMEKO).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/435512
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? ND
social impact