: Radiotherapy is now recognized as a pillar in the fight against cancer. Two different types are currently used in clinical practice: (1) external beam radiotherapy, using high-energy X-rays or electron beams, both in the MeV-range, and (2) intraoperative radiotherapy, using low-energy X-rays (up to 50 keV) and MeV-range electron beams. Versatile detectors able to measure the radiation dose independently from the radiation nature and energy are therefore extremely appealing to medical physicists. In this work, a dosimeter based on a high-quality single-crystal synthetic diamond sample was designed, fabricated and characterized under low-energy X-rays, as well as under high-energy pulsed X-rays and electron beams, demonstrating excellent linearity with radiation dose and dose-rate. Detector sensitivity was measured to be 0.299 ± 0.002 µC/Gy under 6 MeV X-ray photons, and 0.298 ± 0.004 µC/Gy under 6 MeV electrons, highlighting that the response of the diamond dosimeter is independent of the radiation nature. Moreover, in the case of low-energy X-rays, an extremely low limit of detection (23 nGy/s) was evaluated, pointing out the suitability of the device to radiation protection dosimetry.

Pettinato, S., Girolami, M., Stravato, A., Serpente, V., Musio, D., Rossi, M.C., et al. (2023). A Highly Versatile X-ray and Electron Beam Diamond Dosimeter for Radiation Therapy and Protection. MATERIALS, 16(2), 824 [10.3390/ma16020824].

A Highly Versatile X-ray and Electron Beam Diamond Dosimeter for Radiation Therapy and Protection

Girolami, Marco
;
Stravato, Antonella;Serpente, Valerio;Rossi, Maria C;Salvatori, Stefano
2023-01-01

Abstract

: Radiotherapy is now recognized as a pillar in the fight against cancer. Two different types are currently used in clinical practice: (1) external beam radiotherapy, using high-energy X-rays or electron beams, both in the MeV-range, and (2) intraoperative radiotherapy, using low-energy X-rays (up to 50 keV) and MeV-range electron beams. Versatile detectors able to measure the radiation dose independently from the radiation nature and energy are therefore extremely appealing to medical physicists. In this work, a dosimeter based on a high-quality single-crystal synthetic diamond sample was designed, fabricated and characterized under low-energy X-rays, as well as under high-energy pulsed X-rays and electron beams, demonstrating excellent linearity with radiation dose and dose-rate. Detector sensitivity was measured to be 0.299 ± 0.002 µC/Gy under 6 MeV X-ray photons, and 0.298 ± 0.004 µC/Gy under 6 MeV electrons, highlighting that the response of the diamond dosimeter is independent of the radiation nature. Moreover, in the case of low-energy X-rays, an extremely low limit of detection (23 nGy/s) was evaluated, pointing out the suitability of the device to radiation protection dosimetry.
2023
Pettinato, S., Girolami, M., Stravato, A., Serpente, V., Musio, D., Rossi, M.C., et al. (2023). A Highly Versatile X-ray and Electron Beam Diamond Dosimeter for Radiation Therapy and Protection. MATERIALS, 16(2), 824 [10.3390/ma16020824].
File in questo prodotto:
File Dimensione Formato  
materials-16-00824-v3.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 2.76 MB
Formato Adobe PDF
2.76 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11590/451647
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact